Welcome to ManualsDock! Read Millions of manuals for free.

Get 20% off and boost your website's speed with Hostinger Cloud Hosting!

Intex PureSpa SSP-H-20-1C Bubble Massage Inflatable Spa Set User Manual

Intex PureSpa SSP-H-20-1C feature

Intex logo

Intex PureSpa SSP-H-20-1C Bubble Massage Inflatable Spa Set

Intex PureSpa SSP-H-20-1C product

ABOUT Intex
At Intex, they prioritize family time, value, and quality in everything we do. Just like the memories created by the individuals who use them, our reasonably priced items are meant to last. Airbeds, above-ground pools, spas, toys, furniture, boats, and more are all distributed by Intex Recreation Corp. They had more than 50 years of experience behind them and are a member of a global family of businesses.

IMPORTANT SAFETY RULES

When installing and using this electrical equipment, basic safety precautions should always be followed, including the following.

READ AND FOLLOW ALL INSTRUCTIONS

DANGER

  • Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times.
  • Risk of Drowning. Inspect the spa cover regularly for leaks, premature wear, and tear, damage, or signs of deterioration. Never use a worn or damaged cover: it will not provide the level of protection required to prevent unsupervised access to the spa by a child.
  • Risk of Injury. Replace the damaged cord immediately. Do not bury the cord.
  • Risk of Electric Shock. Do not permit any electric appliance, such as a light, telephone, radio, or television, within 3.5 m (11.5 feet) of a spa or hot tub.
  • Risk of Electric Shock. Do not use the spa when it is raining, thundering, or lightning.

WARNING

  • The spa electrical appliance should be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
  • The spa electrical appliance comprises a portable residual current device (PRCD) having a rated residual operating current not exceeding 10 mA. If a leakage current of more than 10 mA is detected, the PRCD will operate and cut off the power supply, in such case, unplug and stop using the spa at once. You must contact the local service center for assistance and/or repair of the product.
  • Parts containing live parts, except parts supplied with safety extra-low voltage not exceeding 12 V, must be inaccessible to a person in the spa.
  • Electrical installation shall fulfill the requirements of local and national standards.
  • Parts incorporating electrical components, except remote control devices, must be located or fixed so that they cannot fall into the spa.
  • To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
  • Children should not use spas or hot tubs without adult supervision.
  • To reduce the risk of child drowning, supervise children at all times. Attach and lock the spa cover after each use.
  • To reduce the risk of injury:
    • The water in a spa should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C (104°F) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.
    • Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 38°C (100°F).
    •  Before entering a spa or hot tub, the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices varies.
    • The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning.
    • Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a spa.
    • Persons using medication should consult a physician before using a spa since some medications may induce drowsiness while other medications may affect heart rate, blood pressure, and circulation.
    • People using medications and/or having an adverse medical history should consult a physician before using a spa or hot tub.
    • Check with a doctor before use if pregnant, diabetic, in poor health, or under medical care.
  • People with infectious diseases should not use a spa or hot tub.
  • To avoid injury exercise care when entering or exiting the spa or hot tub.
  • Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible drowning.
  • Pregnant and possibly pregnant women should consult a physician before using a spa or hot tub.
  • Water temperature in excess of 38°C degree may be injurious to your health.
  • Do not use a spa or hot tub immediately following strenuous exercise.
  • Prolonged immersion in a spa or hot tub may be injurious to your health.
  • When pregnant, soaking in hot water for long periods can harm your fetus. Measure the water temperature before entering. Do not enter the spa if the water is hotter than 38°C (100°F). Do not stay in the spa for longer than 10 minutes.
  • Spa heat in conjunction with alcohol, drugs, or medication can cause unconsciousness.
  • Exit immediately if uncomfortable, dizzy, or sleepy. Spa heat can cause hyperthermia and unconsciousness.
  • The causes, symptoms, and effects of hyperthermia may be described as follows: Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37°C (98.6°F). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include failure to perceive heat; failure to recognize the need to exit the spa or hot tub; unawareness of impending hazards; fetal damage in pregnant women; physical inability to exit the spa or hot tub; and unconsciousness resulting in the danger of drowning.
  • The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
  • Always add chemicals to water, never add water to chemicals. Adding water to chemicals may cause strong fumes or violent reactions and hazardous chemical spray.
  • Never jump or dive into a spa or any shallow body of water.
  • Assembly and disassembly by adults only.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and maintenance must be performed by an adult above 18 years old, and who is familiar with the risk of electric shock.
  • No part of the electrical appliance is to be located above the bath during use.
  • Keep the plug of this product more than 4m away from the spa and at a height of 1.2 m at least.
  • Always unplug this product from the electrical outlet before removing, cleaning, servicing, or making any adjustment to the product, and on rainy days.
  • Do not bury the electrical cord. Locate the cord so it will not be damaged by lawnmowers, hedge trimmers, and other equipment.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard. Use only identical replacement parts when servicing.

PARTS

Before assembling your product, please take a few minutes to check the contents and become familiar with all the parts.

Intex PureSpa SSP-H-20-1C-img1

NOTE: Drawings for illustration purposes only. Actual products may vary. Not to scale

 

 

REF. NO.

 

 

DESCRIPTION

 

 

QTY.

PART NO.
4 ADULTS 6 ADULTS
28404 28406 28408 28410
1 CONTROL BASE 1 12320 12320B 12320 12320B
2 CONTROL BASE BACK COVER 1 11719 11719B 11719 11719B
3 CONTROL PANEL (INCLUDED #4) 1 11930 11930B 11930 11930B
4 CONTROL PANEL BOLT 3 11024 11024B 11024 11024B
5 CONTROL BASE INFLATION CAP 1 11831 11831B 11831 11831B
6 CONTROL PANEL BOLT WRENCH 1 11053 11053 11053 11053
7 SPA/COVER INFLATION HOSE 1 11830 11830 11830 11830
8 SPA CONTROL INLET/OUTLET O-RING 2 11699 11699 11699 11699
9 SPA CONTROL AIR INLET O-RING 1 11687 11687 11687 11687
10 SPA DRAIN PLUG 1 11696 11696B 11696 11696B
11 SPA DRAIN VALVE ADAPTOR 1 11718 11718 11718 11718
12 FILTER CARTRIDGE HOUSING 1 11798 11798 11798 11798
13 FILTER CARTRIDGE 2 11692 11692 11692 11692
14 FILTER CARTRIDGE HOUSING LID 1 11797 11797 11797 11797
15 INLET/OUTLET PLUG 3 11739 11739 11739 11739
16 SPA TUB 1 11842 12260 12106 12258
17 SPA COVER 1 11841 12261 12107 12256
18 SPA COVER INFLATABLE BLADDER (PRE-INSTALLED IN SPA COVER) 1 11689 11689 12108 12108
19 GROUND CLOTH 1 11717 11717 12109 12109
20 CHEMICAL DISPENSER 1 11614 11614 11614 11614
21 TEST STRIPS 1 11855 11855 11855 11855
22 WRENCH 1 11742 11742 11742 11742
23 PRESSURE GAUGE 1 11741 11741 11741 11741
24 INFLATION HOSE ADAPTOR 1 11829 11829 11829 11829
25 MALE BUCKLE 6 11698 11698B 11698 11698B
26 FEMALE BUCKLE 6 11799 11799B 11799 11799B
27 DEFLATION OUTLET CAP 1 11934 11934B 11934 11934B
28 DEFLATION HOSE ADAPTOR 1 11935 11935 11935 11935
29 SPA FILTER MOTOR 1 11886 11886B 11886 11886B

PRODUCT SPECIFICATIONS

Maximum seating capacity: 4 adults 6 adults
Water capacity: 210 gal (795 L) 290 gal (1098 L)
Inner/outer diameter: 57/77 in (145/196 cm) 65/85 in (165/216 cm)
Height: 28 in (71 cm)
Bubble air blower: 1.1 HP / 220-240 V / 50 Hz
Filter pump flow rate: 460 gal/hr (1,741 L/hr)
Heater power: 2,200 Watts / 220-240 V / 50 Hz
Temperature range: 20ºC – 40ºC (68ºF – 104ºF)
Temperature rise: 1.5-2.5ºC/hr (3ºF – 4.5ºF/hr) 1-2ºC/hr (2ºF – 3.5ºF/hr)
A number of Bubble Jets: 120 (28404)

 

140 (28406)

140 (28408)

 

170 (28410)

Spa tub recommended working air pressure: 0.083 bar (1.2 psi)

Cord-connected spa with pump, heater, blower, built-in hard water treatment, and control panel. This product requires a minimum of 13 Amps. If the circuit breaker trips, please check that no other appliances or other large loads are on the same circuit as the spa.

SET UP

Site preparation and requirements

  • The spa can be installed indoors or outdoors. For household use only.
  • Make sure the area is free of sharp objects under or around the spa.
  • Provide a properly located power outlet to connect the spa and allow easy access for periodic testing of the cord-mounted RCD.
  • Make sure there is enough clearance around the spa for full access to the spa equipment for maintenance and/or service.
  • The area shall facilitate draining purposes during long-term spa storage.

Additional requirements for indoor installation

  • Make sure the floor can support the full weight of the filled spa with the maximum number of occupants.

Check with a qualified contractor or a structural engineer to verify this requirement.

  • Make sure the floor is a water-resistant and non-slip surface. Do not install the spa on carpet or other materials that will be damaged by moisture, or condensation.
  • Do not install the spa indoors on a second floor above fi finished living space due to the possibility of water and humidity damage.
  • Humidity is a natural side effect of indoor spa installation. The room shall be properly ventilated to allow moisture to escape. Install a ventilating system to prevent excess condensation and moisture in the room.

Additional requirements for outdoor installation

  • Spa owners may need to comply with local or state laws relating to childproof fencing, safety barriers, lighting, and other safety requirements. Contact your local building code enforcement office for further details.
  • Make sure the surface is level, flat, smooth, and strong enough to support the full weight of the filled spa.
  • Do not set up the spa on grass or dirt, as this increases the amount of debris entering the spa, and damages the sea floor.
  • Do not expose the spa to direct sunlight for an extended period of time.
  • It is possible to install and leave the spa outside at a temperature not lower than 4°C (39°F) provided the water temperature inside the spa is higher than 4°C (39°F) and the water inside the circulation system, pump, and pipe is not frozen. Put a “temp barrier mat” between the sea floor and the ground to prevent heat loss from the bottom of the spa and provide better heat retention.

FAQs Intex PureSpa SSP-H-20-1C

Q: What is the Intex PureSpa SSP-H-20-1C?

A: The Intex PureSpa SSP-H-20-1C is an inflatable hot tub/spa that is designed for both indoor and outdoor use. It has a capacity of up to four people and includes a built-in hard water treatment system, a control panel, and an insulated cover.

Q: What are the dimensions of the Intex PureSpa SSP-H-20-1C?

A: The dimensions of the Intex PureSpa SSP-H-20-1C are 77 inches in diameter and 28 inches in height.

Q: What is the weight of the Intex PureSpa SSP-H-20-1C?

A: The weight of the Intex PureSpa SSP-H-20-1C when it is filled with water is approximately 2,200 pounds.

Q: What is the seating capacity of the Intex PureSpa SSP-H-20-1C?

A: The Intex PureSpa SSP-H-20-1C has a maximum seating capacity of four people.

Q: Does the Intex PureSpa SSP-H-20-1C come with a cover?

A: Yes, the Intex PureSpa SSP-H-20-1C comes with an insulated cover to help maintain the temperature of the water.

Q: Does the Intex PureSpa SSP-H-20-1C come with a pump?

A: Yes, the Intex PureSpa SSP-H-20-1C comes with a pump that is used to inflate the spa and circulate the water.

Q: How long does it take to set up the Intex PureSpa SSP-H-20-1C?

A: The Intex PureSpa SSP-H-20-1C can be set up in approximately 20 minutes.

Q: What is the temperature range of the Intex PureSpa SSP-H-20-1C?

A: The temperature range of the Intex PureSpa SSP-H-20-1C is between 68 and 104 degrees Fahrenheit.

Q: Does the Intex PureSpa SSP-H-20-1C have a warranty?

A: Yes, the Intex PureSpa SSP-H-20-1C comes with a one-year limited warranty.

Q: Can the Intex PureSpa SSP-H-20-1C be used in the winter?

A: The Intex PureSpa SSP-H-20-1C can be used in the winter, but it is recommended to use it in temperatures above 40 degrees Fahrenheit to prevent damage to the spa and its components.

For more manuals by Amazon, Visit Manualsdock

[embeddoc url=”https://manualsdock.com/wp-content/uploads/2023/03/Intex-PureSpa-SSP-H-20-1C.pdf” download=”all”]

Leave a Comment