Important Instructions

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  • Read all instructions before using the appliance.
  • IMPORTANT – This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
  • To avoid fire or shock hazards, plug the appliance directly into a 120V AC electrical outlet.
  • Keep the cord out of heavy traffic areas. To avoid fire hazards, NEVER put the cord under rugs, near heat registers, radiators, stoves, or heaters.
  • To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.
  • Extreme caution is necessary when any appliance is used by or near children or people with disabilities and whenever the appliance is left operating unattended.
  • Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning, or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
  • NEVER drop or insert any object into any openings.
  • DO NOT run the cord under the carpeting.
  • DO NOT cover the cord with throw rugs, runners, or similar coverings.
  • DO NOT route the cord under furniture or appliances. Arrange the cord away from the traffic area and where it will not be tripped over.
  • DO NOT operate any appliance with a damaged cord or plug, if the motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer Service at 1.866.603.5900 for assistance.
  • Use appliances only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
  • DO NOT use outdoors.
  • DO NOT place anything on top of the unit.
  • NEVER block the air openings, grills/outlets, or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user-serviceable parts. All servicing should be performed by qualified personnel only.
  • WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
  • WARNING: Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus. Always disconnect the power before replacing the lamp or servicing it. Replace Lamp With Lamp Manufactured by Guardian Technologies.
  • Always unplug the unit before cleaning or servicing it in any way.
  • CAUTION: Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.

PRODUCT SPECIFICATIONS AND PARTS

GermGuardian AC5300 Air Purifier 1

CONTROLS

GermGuardian AC5300 Air Purifier 2

GermGuardian AC5300 Air Purifier 3

REPLACEMENT PARTS

GermGuardian AC5300 Air Purifier 4

AIR CLEANING SYSTEM

Improve your indoor air quality with your new germguardian® Air Cleaning System. Multiple levels of cleaning include a combination filter that captures allergens, and a Charcoal filter to remove odors. UV-C light technology enhances germ-killing.

Pre-Filter – Captures initial dust and allergen particles.

Activated Carbon Filter – Charcoal/Activated Carbon contributes to the control and prevention of the growth of bacteria, germs, and mold.

UV-C Light – UV-C light technology works with Titanium Dioxide (TiO2) to enhance the elimination of airborne germs. TiO2 is activated by the UV-C light to decompose the remaining odor molecules caused by smoking, cooking, and pets.

Pre-filter and Carbon Filter are combined into one layer that attaches to the Filter.

AIR CLEANING LAYERS

GermGuardian AC5300 Air Purifier 5

OPERATING INSTRUCTIONS

BEFORE OPERATING THE AIR PURIFIER

  • Select a firm, level, and flat location for the air purifier.
    • For proper airflow, locate the unit at least 1 foot from any wall or furniture.
    • Make sure none of the grills are blocked.
  • Plug the power cord into a 120V AC outlet.

IMPORTANT
When moving the air purifier, always lift the unit by the carrying handle located on the back.

Filter Replacement Indicator
The Replace HEPA light on the control panel will illuminate and flicker indicating that it is time to replace your filter. Replace the filter according to directions (E-7) then press and hold the Timer Set button for 3 seconds to reset the system.

UV Bulb Replacement Indicator
The circular blue light on the front panel of the purifier will flicker when it’s time to replace the bulb. Replace the bulb according to directions (E-8), then press and hold the UV Mode button for 3 seconds to reset the system.

Control Panel Beep/Sound
The sound emitted from pressing the buttons on the control panel can be turned off/on by holding the Speed button for 3 seconds.

FILTER REPLACEMENT

  1. Turn off and unplug the unit.
  2. GermGuardian AC5300 Air Purifier 6 Press the lock and release button and remove the rear cover from the unit.
  3. Remove the used Combination Filter (Filter C) and dispose of it in the garbage
  4. Insert filter system into the unit. Consult the arrow on the filter for the correct installation direction.
  5. Reattach the rear cover of the unit and securely latch it into place.

CHECKING AND MAINTAINING FILTER

Maintain the filter by checking it frequently. Depending on air quality conditions, you may need to replace it more frequently. Vacuum the carbon filter layer as needed to remove loose debris and dust and to help prolong the life of your filter. To check the status of the filter, peel back the carbon layer to expose the pleated filter. If the filter is no longer white and is covered in grey dust/dirt it should be replaced.

IMPORTANT
Do NOT try to wash and re-use the Combination Filter.

IMPORTANT
To maintain the performance of the air cleaner, use Guardian Technologies GENUINE Replacement Parts only.

INSTALLING & REMOVING UV-C BULB

UV Bulb Replacement Indicator: The UV light on the display will flash when it is time to replace the UV bulb.

GermGuardian AC5300 Air Purifier 7