Welcome to ManualsDock! Read Millions of manuals for free.

EverStart JUS750CE Jumper Starter User Guide

EverStart JUS750CE Jumper Starter-Featured-images

EverStart logo

EverStart JUS750CE Jumper Starter

EverStart JUS750CE Jumper Starter-Product-img

About Everstart
EverStart JUS750CE Jumper Starter batteries are produced by Johnson Controls. These are long-lasting, high-quality, and require little care. AGM and lead acid batteries are both available in the EverStart line. EverStart Plus and EverStart Maxx are two of the most well-liked AGM (absorbed glass mat) battery variants.

Looking for a variety of jumper starters? click to have diverse options for your individual needs.

FEATURESEverStart JUS750CE Jumper Starter 001

  1. Negative (–) Black Clamp
  2. Backlit LCD Screen
  3. Built-in 120 Volt AC Charger (under protective cover)
  4. 2-LED White Area Light
  5. Positive (+) Red Clamp
  6. USB Charging Ports
  7. Compressor Power Button
  8. Decrease Compressor Pressure Control Button (–)
  9. USB Power Button
  10. Area Light Power Button
  11. Increase Compressor Pressure Control Button (+)
  12. Jump Starter Power Switch
  13. Nozzle Adapter
  14. Air Hose Storage
  15. Air Hose and Sure Fit® Nozzle

Visit: EverStart SL097 Jump Starter

DIGITAL LCD SCREENEverStart JUS750CE Jumper Starter 02

SAFETY GUIDELINES / DEFINITIONS

DANGER: Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or property damage.

RISK OF UNSAFE OPERATION.

When using tools or equipment, basic safety precautions should always be followed to reduce the risk of personal injury. Improper operation, maintenance, or modification of tools or equipment could result in serious injury and property damage. There are certain applications for which tools and equipment are designed. The manufacturer strongly recommends that this product NOT be modified and/or used for any application other than for which it was designed. Read and understand all warnings and operating instructions before using any tool or equipment.

WARNING: Read all instructions before operating the jump starter. Failure to follow all instructions listed below may result in electric shock, fire, and serious injury.

IMPORTANT SAFETY INSTRUCTIONS

GENERAL SAFETY WARNINGS AND INSTRUCTIONS

  • This unit was designed for household use only.
    WARNING – Risk of fire, electric shock, burst hazard, or injury to persons or property:
  • Avoid dangerous environments. Don’t use appliances in damp locations. Don’t use appliances in the rain.
  • Keep children away. All visitors should be kept at a distance from the work area.
  • Dress properly. Do not wear loose clothing or jewelry. They can be caught in moving parts. Rubber gloves and substantial, non-skid footwear are recommended when working outdoors. Wear a protective hair covering to contain long hair.
  • Store idle appliances indoors. When not in use, appliances should be stored indoors in dry, and high or locked-up places – out of reach of children.
  • Don’t abuse the cord. Never carry the appliance by a cord or yank it to disconnect it from the receptacle. Keep cord from heat, oil, and sharp edges.
  • Disconnect appliances. Disconnect the appliance from the power supply when not in use, before servicing, and when changing accessories.
  • Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuits or outlets to be used. Receptacles are available having built-in GFCI protection and may be used for this measure of safety.
  • Use of accessories and attachments. The use of any accessory or attachment not recommended for use with this appliance could be hazardous. Refer to the accessory section of this manual for further details.
  • Stay alert. Use common sense. Do not operate this equipment when you are tired or impaired.
  • Check for damaged parts. Any part that is damaged should be replaced by the manufacturer before further use. Do not use the tool if the switch does not turn it on and off. Contact the manufacturer at 1-877-571-2391 for more information.
  • Do not operate this appliance near flammable liquids or in gaseous or explosive atmospheres. Motors in these tools normally spark, and the sparks might ignite fumes.
  • Never submerge this unit in water; do not expose it to rain, or snow or use it when wet.
  • To reduce the risk of electric shock, disconnect the unit from any power source before attempting maintenance or cleaning. Turning off controls without disconnecting will not reduce this risk.
  • This equipment employs parts (switches, relays, etc.) that produce arcs or sparks. Therefore, if used in a garage or enclosed area, the unit MUST be placed not less than 18 inches above the floor.
  • Do not insert foreign objects into the USB ports.

SPECIFIC SAFETY INSTRUCTIONS FOR CHARGING THIS UNIT

  • IMPORTANT: This unit is delivered in a partially charged state. Fully charge the unit with a household extension cord for a full 24 hours or until the battery status icon shows 4 solid bars before using it for the first time. You cannot overcharge the unit using the AC charging method.
  • To recharge this unit, use only the built-in AC charger.
  • All functions should be turned off when the unit is charging or not in use. Make sure all switches are in the OFF position before connection to a power source or load.

EXTENSION CORDS:

WARNING: Use of improper extension cord could result in a risk of fire and electric shock. When using an extension cord, make sure that the pins of the extension cord are the same number, size, and shape as those in the charger; and be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. The following table shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.EverStart JUS750CE Jumper Starter 03

  • When an extension cord is used, make sure that:
    • the pins of the extension cord are the same number, size, and shape as those in the charger,
    • the extension cord is properly wired and in good electrical condition,
    • the wire size is large enough for the AC rating of the charger.

CAUTION – To reduce the risk of injury or property damage: Pull the extension cord by the plug rather than the cord when disconnecting from the built-in 120-volt AC charger or the AC outlet.

SPECIFIC SAFETY INSTRUCTIONS FOR JUMP STARTERS

WARNING: Burst hazard Do not use the unit for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to persons and damage property. Use the unit for charging/boosting a lead-acid battery only. It is not intended to supply power to a low-voltage electrical system other than in a starter-motor application. Use of an attachment not supplied, recommended, or sold by the manufacturer specifically for use with this unit may result in a risk of electrical shock and injury to persons.

WARNING: Risk of explosive gases

  • Working in the vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases during normal battery operation. For this reason, it is of the utmost importance that each time before using the jump-starter you read this manual and follow instructions exactly.
  • To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in the vicinity of the battery. Review cautionary markings on these products and on the engine.

CAUTION – To reduce the risk of injury or property damage:

  • NEVER ATTEMPT TO JUMP-START OR CHARGE A FROZEN BATTERY.
    Vehicles that have onboard computerized systems may be damaged if the vehicle battery is jump-started. Before jump-starting, read the vehicle’s owner’s manual to confirm that external-starting assistance is suitable.
  • Never smoke or allow a spark or flame in the vicinity of the vehicle battery, engine, or power station
  • Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons.
  • Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead acid battery. A lead acid battery can produce a short circuit current high enough to weld a ring, or similar metal object, to skin, causing a severe burn.
  • Do not wear vinyl clothing when jump-starting a vehicle. Friction can cause dangerous static electrical sparks.
  • Be extra careful to avoid dropping a metal tool onto the battery. It might spark or short-circuit the battery or another electrical part and could cause an explosion.
  • Jump-start procedures should only be performed in a safe, dry, well-ventilated area.
  • Always store battery clamps when not in use. Never touch battery clamps together. This can cause dangerous sparks, power arcing, and/or explosions.
  • When using this unit close to the vehicle’s battery and engine, stand the unit on a flat, stable surface, and be sure to keep all clamps, cords, clothing, and body parts away from moving vehicle parts.
  • Never allow red and black clamps to touch each other or another common metal conductor — this could cause damage to the unit and/or create a sparking/explosion hazard.
    • For negative-grounded systems, connect the positive (red) clamp to the positive ungrounded battery post and the negative (black) clamp to the vehicle chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gauge metal part of the frame or engine block.
    •  For positive-grounded systems, connect the negative (black) clamp to the negative
  • If the clamps are connected incorrectly about polarity, the backlit LCD screen will display the Battery Status Icon, Battery Voltage Indicator, and Clamp Icons. The Alarm Icon, the “+” and “–” signs, and the Reverse Polarity Icons will flash and the unit will sound a continuous alarm until the clamps are disconnected. Disconnect the clamps and reconnect to the battery with the correct polarity.
  • Always disconnect the negative (black) jumper cable first, followed by the positive (red) jumper cable, except for positive grounded systems.
  • Do not expose the battery to fire or intense heat since it may explode. Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire).
  • Place this unit as far away from the battery as cables permit.
  • Never allow battery acid to come in contact with this unit.
  • Do not operate this unit in a closed area or restrict ventilation in any way.
  • This system is designed to be used only on vehicles with a 12-volt DC battery system. Do not connect to a 6-volt or 24-volt battery system.
  • This system is not designed to be used as a replacement for a vehicular battery. Do not attempt to operate a vehicle that does not have a battery installed.
  • Excessive engine cranking can damage a vehicle’s starter motor. If the engine fails to start after the recommended number of attempts, discontinue jump-start procedures and look for other problems that may need to be corrected.
  • Do not use this jump starter on a watercraft. It is not qualified for marine applications.
  • Although this unit contains a non-spillable battery, it is recommended that the unit be kept upright during storage, use, and recharging. To avoid possible damage that may shorten the unit’s working life, protect it from direct sunlight, direct heat, and/or moisture.

SPECIFIC SAFETY INSTRUCTIONS FOR THE USB PORTS

  • Do not insert foreign objects into the USB Ports.
  • Do not attach USB hubs or more than one personal electronic device to each USB Port.
  • Do not use this unit to operate appliances that require more than 2.1 amps in total to operate from the USB Ports.
  • Some household USB-powered electronics will not operate with this unit.

SPECIFIC SAFETY INSTRUCTIONS FOR COMPRESSORS

CAUTION – To reduce the risk of injury or property damage:

  • Never leave the compressor unattended while in use.
  • Do not operate the compressor continuously for longer than approximately 10 minutes, depending on ambient temperatures, as it may overheat. This could damage the compressor. Follow the instructions in the “Portable Compressor” section.

WARNING – Burst hazard: Bursting articles can cause serious injury.

  • Carefully follow instructions on articles to be inflated.
  • Never exceed the recommended pressure listed in instructions on articles to be inflated. If no pressure is given, contact the article manufacturer before inflating.
  • Monitor the pressure at all times on the LCD screen.

FIRST AID

When working with lead acid batteries, always make sure immediate assistance is available in case of an accident or emergency. Always have protective eyewear when using this product: contact with battery acid may cause blindness and/or severe burns. Be aware of first aid procedures in case of accidental contact with battery acid. Have plenty of fresh water and soap nearby in case battery acid contacts the skin.

  • Skin: If battery acid comes in contact with the skin, rinse immediately with water, then wash thoroughly with soap and water. If redness, pain, or irritation occurs, seek immediate medical attention.
  • Eyes: If battery acid comes in contact with your eyes, flush your eyes immediately, for a minimum of 15 minutes, and seek immediate medical attention
  • LCD liquid crystal display: If liquid crystal comes in contact with your skin: Wash the area off completely with plenty of water. Remove contaminated clothing. If liquid crystal gets into your eye: Flush the affected eye with clean water and then seek medical attention. If liquid crystal is swallowed: Flush your mouth thoroughly with water. Drink large quantities of water and induce vomiting. Then seek medical attention.

Visit: EverStart SL097 Jump Starter

SAVE THESE INSTRUCTIONS

OVERVIEW

COMMON ACTIONS AND UNIT RESPONSES
The following actions turn the unit on and activate the LCD screen:

Press the LED Area Light Power Button. (Refer to the “LED Area Light” section.) A beep will sound and the Area Light will turn on. The backlight will turn on for 10 seconds (only). The LCD screen will continue to display the Battery Status Icon and Battery Voltage Indicator. The unit remains on until the LED Area Light Power Button is pressed again

 

 

 

to turn it off.

Press the USB Power Button.

 

 

 

(Refer to the “USB Ports” section.)

A beep will sound and the USB Ports will turn on. The backlight will turn on for 10 seconds (only). The LCD screen will display the Battery Status Icon, Battery Voltage Indicator, and

 

 

 

USB Icon; indicating the two USB Ports are active. The unit remains on until the USB Power Button is pressed again to turn it off.

Press the Compressor Power Button. (Refer to the “Portable Compressor” section.) A beep will sound and the backlit LCD screen will display the Battery Status Icon, “XXX” PSI, and the Compressor Icon. If no further actions are taken after 1 minute, the unit will display the Battery Status Icon and Battery Voltage Indicator for 10 seconds before automatically turning off.
Whenever the clamps are properly connected to a battery (refer to the “Jump Starter” section) … a beep will sound and the backlit LCD screen will display the Battery Status Icon, Battery Voltage Indicator, the Clamp Icons, and the “+” and “–” signs, as well as the flashing Jump Starter Icon. The unit remains on until the clamps are disconnected from the battery.
If the Jump Starter Power Switch is rotated to the on position and the clamps are not connected to a battery (refer to the “Jump Starter” section) … a two-second warning will sound every 10 seconds. The backlit LCD screen will display the Battery Status Icon, the Battery Voltage Indicator, the Clamp Icons, and the “+” and “–” signs. The Alarm Icon and the Jump Starter Icon will flash. The unit remains on until the Jump Starter Power Switch is switched off and then displays the battery status icon and the voltage of the digital display for 10 seconds before automatic shutdown.
If the clamp connections to the battery’s positive and negative terminals are reversed (refer to the “Jump Starter” section) … the backlit LCD screen will display the Battery Status Icon, Battery Voltage Indicator, and Clamp Icons. The Alarm Icon, the

 

 

 

“+” and “–” signs and the Reverse Polarity Icons will flash and the unit will sound a warning continuously until the clamps are disconnected from the battery.

When the unit is charging

 

 

 

or recharging using the built-in 120 Volt AC Charger (refer to the “Charging/Recharging” section)

… the backlight will turn on for 10 seconds (only). The LCD screen will continue to display the Battery Status Icon and Battery Voltage Indicator. The bars on the Battery Status Icon will change from empty to solid (bottom to top) repeatedly.

Note: The unit will automatically power off once ALL the functions are turned off.

VIEWING BATTERY STATUS
The Battery Status Icon and Battery Voltage Indicator indicate the battery charge level as follows.EverStart JUS750CE Jumper Starter 04

  • If the battery charge level is at full capacity, four solid bars will display.
  • If the battery is partially charged, two or three solid bars will be displayed.
  • If the battery is nearly empty, one solid bar will display. The unit should be charged at this time.
  • If the battery is empty, four blank bars will display. The unit MUST be charged at this time or the unit’s built-in low-voltage protection will activate. The empty Battery Status Icon will flash for a short period before automatic shutdown. The unit will not operate until the battery is recharged.

CHARGING/RECHARGING

This unit is delivered in a partially charged state – you must fully charge it before using it for the first time. Initial AC charge should be for 24 hours or until the Battery Status Icon shows 4 solid bars.

Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. All batteries lose energy from self-discharge over time and more rapidly at higher temperatures. Therefore, batteries need periodic charging to replace the energy lost through self-discharge. When the unit is not in frequent use, the manufacturer recommends the battery should be recharged at least every 30 days and after each use.

CAUTION – Risk of property damage: Failure to keep the battery charged will cause permanent damage and result in poor jump-starting performance.

IMPORTANT NOTES:

  • Recharging the battery after each use will prolong battery life; frequent heavy discharges between recharges and/or overcharging will reduce battery life.
  • Make sure all other unit functions are turned off during recharging, as this can slow the recharging process.
  • If you know the unit is discharged, but the battery icon displays four solid bars as if the unit is fully charged when connected to a charging power source, this may be due to the internal battery having a high impedance. The manufacturer suggests leaving the unit charging for 40 hours using the built-in AC charger before use.

Charging/Recharging Use the Built-In 120 Volt AC Charger and AC Extension Cord (not included)

  1. Lift the protective cover of the built-in 120 Volt AC Charger (refer to the “Features section to locate). Connect an extension cord to the unit. Plug the other end of the cord into a standard 120-volt AC wall outlet. When the unit is properly connected to an AC power source, the LCD screen will display the following:EverStart JUS750CE Jumper Starter 05
  2. The bars on the Battery Status Icon represent the charge level of the unit’s internal battery. The bars on the Battery Status Icon will change from empty to solid
    (bottom to top) repeatedly to indicate the unit is charging. The backlight will turn on for 10 seconds (only).
  3. Charge for approximately 24 hours or until the Battery Status Icon shows 4 solid bars.
  4. When charging is complete, unplug the AC extension cord from the AC outlet and then disconnect it from the unit.

JUMP STARTER

This unit is equipped with a jump starter power switch that allows energy to flow only when proper connections are made to the battery and frame.

  1. For negative-grounded systems, connect the positive (red) clamp to the positive ungrounded battery post and the negative (black) clamp to the vehicle chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gauge metal part of the frame or engine block.
  2. For positive-grounded systems, connect the negative (black) clamp to the negative ungrounded battery post and the positive (red) clamp to the vehicle chassis or engine block away from the battery. Do not connect the clamp to the carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gauge metal part of the frame or engine block.

IMPORTANT: Make sure the Compressor Power Button has been turned off before attempting to use the unit as a Jump Starter.
WARNING – To reduce the risk of serious injury or property damage:

  • Follow all safety instructions found in the “Specific Safety Instructions for Jump Starters” section of this instruction manual.
  • Never touch red and black clamps together. This can cause dangerous sparks, power arcing, and/or explosions.
  • If the clamps are connected incorrectly about polarity, the unit will sound
    a continuous alarm until the clamps are disconnected. The backlit LCD Screen will display the Battery Status Icon, the Battery Voltage Indicator, and the Clamp Icons. The “+” and”–” signs above the Clamp Icons, the Arrow Icons, and the Alarm Icon will flash. The backlit LCD screen will display the following:EverStart JUS750CE Jumper Starter 06

CAUTION: The unit will suffer permanent damage if the Jump Starter Power Switch is turned on while the clamps are connected with reverse polarity. Disconnect the clamps and reconnect to the battery with the correct polarity.

  • If the Jump Starter Power Switch is turned on and the unit detects that the clamps are not connected to a battery, a two-second warning will sound every 10 seconds. The LCD screen will display the Battery Status Icon, the Battery Voltage Indicator, and the Clamp Icons with the “+” and”–” signs. The Alarm Icon and the Jump Starter Icon will flash. The backlit LCD screen will display the following:EverStart JUS750CE Jumper Starter 07
  • Turn off the Jump Starter Power Switch; connect the clamps to the battery, making sure the clamps are connected with correct polarity; then turn the Jump Starter Power Switch back on.
  • Always disconnect the negative (black) jumper cable first, followed by the positive (red) jumper cable, except for positive grounded systems.

PROCEDURE

Take the following steps, observing all cautions and warnings in the “Important Safety Instructions” section at the front of this manual.

  1. Turn off vehicle ignition and all accessories (radio, A/C, lights, connected cell phone chargers, etc.). Place the vehicle in “park” and set the emergency brake.
  2. Make sure the jump-starter power switch is in the off position.
  3. Remove jumper clamps from clamp tabs. Connect the red clamp first, then the black clamp.
  4. Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (negative battery terminal is connected to chassis) (MOST COMMON)
    • Connect the positive (+) red clamp to the vehicle battery’s positive terminal.
    • Connect negative (–) black clamp to the chassis or a solid, non-moving, metal vehicle component or body part. Never clamp directly to the negative battery terminal or moving part. Refer to the automobile owner’s manual.
  5.  Procedure for jump-starting POSITIVE GROUND SYSTEMSProcedure for jump-starting POSITIVE GROUND SYSTEMS
    NOTE: In the rare event that the vehicle is to be started as a Positive Grounded System (positive battery terminal is connected to chassis), replace steps 4a and 4b above with steps 5a and 5b, then proceed to step 6.

     

    • Connect the negative (–) black clamp to the vehicle battery’s negative terminal.
    • Connect positive (+) red clamp to the vehicle chassis or a solid, non-moving, metal vehicle component or body part. Never clamp directly to the positive battery terminal or moving part. Refer to the automobile owner’s manual.
  6. When the clamps are connected properly, the backlit LCD screen will display the following to indicate the unit is ready to jump-start:EverStart JUS750CE Jumper Starter 08
  7. The Battery Status icon, Battery Voltage Indicator, Clamp Icons, and the “+” and”–” signs are light solid. The jump starter icon will flash to indicate the clamps are properly connected.
  8. Turn the Jump-Starter Power Switch on. When the Jump-Starter Power Switch is turned on, the Engine Icon lights solid indicating it is time to start the vehicle. Turn on the ignition and crank the engine in 5-6 second bursts until the engine starts. The backlit LCD screen will display the following:EverStart JUS750CE Jumper Starter 09
  9. The Battery Status Icon, the Battery Voltage Indicator, the Jump Starter Icon, Clamp Icons, and the “+” and”–” signs light solid to indicate the unit is jump-starting.
  10. Turn the Jump-Starter Power Switch off.
  11. Disconnect the negative (–) engine or chassis clamp first, then disconnect the positive (+) battery clamp.

IMPORTANT: Always turn the unit off when not in use. Recharge this unit fully after each use.
CAUTION – To reduce the risk of property damage:

  • Vehicles that have onboard computerized systems may be damaged if the vehicle battery is jump-started. Before jump-starting this type of vehicle, read the vehicle manual to confirm that external starting assistance is advised.
  • Excessive engine cranking can damage the vehicle‘s starter motor. If the engine fails to start after the recommended number of attempts, discontinue the jump-start procedure and look for other problems that need to be corrected.
  • If the vehicle fails to start, turn off the ignition, turn off the Jump-Starter Power Switch, disconnect the jump-start system’s leads, and contact a qualified technician to investigate why the engine did not start.

LED AREA LIGHT

The built-in LED Area Light consists of two LEDs on the front of the unit. It is controlled by the Area Light Power Button on the control panel (refer to the “Features” to locate).

  1. Press the Area Light Power Button once to turn the light on.
  2. Press the Area Light Power Button again to turn the area light off.

When the Area Light Power Button is pressed to turn it on, a beep will sound. The backlit LCD screen will turn on for 10 seconds (only) and will then continuously display the Battery Status Icon and the Battery Voltage Indicator. Periodically check the unit’s battery status on the backlit LCD screen. Four solid bars in the battery icon indicate a full battery.

When the battery level is nearly empty with only one solid bar or empty with 4 empty bars, the unit must be recharged at this time or the unit’s built-in low-voltage protection will activate. The empty Battery Status Icon will flash for a short period before automatic shutdown.

IMPORTANT: Make sure the Area Light is turned off when the unit is being recharged or stored.

USB PORTS

The USB Power Button and the two USB Ports are located on the front of the unit. The USB Ports provide a total of 2.1A (5V each). When the USB Ports are in use, the unit will monitor for the following USB fault conditions on both USB Ports: low battery voltage fault, overload, and short circuit. If a fault condition exists in either of the USB Ports, the backlit LCD screen will continuously display the following:EverStart JUS750CE Jumper Starter 010

The Fault Icon will flash. The USB Ports will automatically shut down. Should this occur, disconnect the USB-powered device and press the USB Power Button again to turn off the USB Ports immediately. Make sure the unit does not need to be recharged. Allow the unit to cool down for several minutes before attempting to use the USB Ports again. If a fault occurs again, make sure that the total draw of the USB devices plugged into the USB Ports does not exceed 2.1A (5V each).

If an individual USB device is within specifications and the fault occurs, have the USB device checked for malfunction and do not continue to use it with these USB Ports.

USING THE USB PORTS

  1. Press the USB Power Button to turn on both USB Ports. A beep will sound, the backlight will turn on for 10 seconds (only) and the LCD screen will continuously display the following:EverStart JUS750CE Jumper Starter 011
  2. The Battery Status Icon and Battery Voltage Indicator will light solid, as well as the USB Icon, indicating the USB ports are ready to use.
  3. Plug the USB-powered device into the USB power port(s) and operate normally.
  4. Press the USB power button again to turn off the USB Ports.

Periodically check the unit’s battery status on the backlit LCD screen. Four solid bars in the battery icon indicate a full battery. When the battery level is nearly empty with only one solid bar or empty with 4 empty bars, the unit must be recharged at this time or the unit’s built-in low-voltage protection will activate. The empty Battery Status Icon will flash for a short period before automatic shutdown.

IMPORTANT: Make sure the USB Ports are turned off when the unit is being recharged or stored.

Notes:  This unit’s USB Ports do not support data communication. They only provide power to external USB-powered devices. The two USB Ports provide a total of 2.1A (5V each). Some household USB-powered electronics will not operate with this unit.

PORTABLE COMPRESSOR
The built-in 12-volt DC compressor is the ultimate compressor for all vehicle tires, trailer tires, and recreational inflatables. A nozzle adaptor is supplied that screws onto the end of the Sure Fit® nozzle at the free end of the compressor hose. The compressor hose with tire fitting is stored in the compressor hose storage compartment. Refer to the “Features” illustration for the locations of the compressor hose.

The Compressor Power Button and Increase (+) and Decrease (–) Compressor Pressure Control Buttons are located on the control panel on the front of the unit. Before proceeding, check the unit’s battery status on the LCD screen. Four solid bars in the battery icon indicate a full battery. When the battery level is nearly empty with only one solid bar, the unit MUST be recharged before use or the unit’s built-in low voltage protection will activate. The empty Battery Status Icon will flash for a short period before automatic shutdown.

The compressor is capable of inflating up to 120 pounds per square inch (psi) pressure. The compressor can operate long enough to fill up to 3 average-sized tires before the battery must be recharged. Return the hose to the storage compartment after use.

IMPORTANT: Make sure the Jump Starter Power Button has been turned off before attempting to use the unit as a Compressor.

WARNING – To reduce the risk of serious injury or property damage: Follow all safety instructions found in the “Specific Safety Instructions for Compressors” section of this instruction manual.

CAUTION – To reduce the risk of serious injury or property damage: When the compressor is operated at a low PSI, the unit may start at low and gradually rev up. When the compressor is operated at higher PSIs, the unit may operate normally for several minutes, then rev down for a few minutes before returning to normal operation. This feature protects the unit from overheating during normal use. In any event, do not operate the compressor continuously for longer than 10 minutes, as it may overheat. This could damage the compressor.

If the compressor must be operated for longer periods: every 10 minutes press the Compressor Power Button to turn the compressor off, then restart after a cooling down period of approximately 30 minutes.

Inflating Tires or Products With Valve Stems

  1. Screw the Sure Fit® nozzle onto the valve stem. Do not over-tighten.
  2. Press the Compressor Power Button. A beep will sound and the backlit LCD screen will display the following:
  3. EverStart JUS750CE Jumper Starter 012
  4. The Compressor Icon will light and the digital display will alternately show the flashing pre-set psi value (that was last set by the compressor pressure control buttons) and the current pressure of the item being inflated (which will light solid).
  5. Press the “+” and “–” Pressure Control Buttons to set the desired pressure from a range of pre-set values (between 3 and 120), which will be displayed on the backlit LCD screen. The unit will sound a beep with each press of the buttons (holding the button speeds up the upward or downward value selection). Once the desired pressure has been entered, release the button and the flashing digital display will show the newly selected pressure, as follows:EverStart JUS750CE Jumper Starter 013
  6. The newly selected value is now stored in the unit’s memory until it is manually reset.
  7. Press the Compressor Power Button once more to begin inflating. The Compressor Icon will flash and the digital display will only show the current pressure value (which will be light solid) to indicate the compressor is activated. Monitor the pressure on the LCD screen.
    IMPORTANT NOTE: To interrupt during inflation, press the Compressor Power Button again.
  8. When the desired pre-set pressure is reached, the compressor will automatically stop.
  9. Press the Compressor Power Button again to turn off the unit.
  10. Unscrew and remove the Sure Fit® nozzle from the valve stem.
  11. Allow the unit to cool, then recharge before storing away.
  12. Store the compressor hose and Sure Fit® nozzle in the storage compartment.

Inflating Other Inflatables Without Valve Stems
Inflation of other items requires the use of the nozzle adapter.

  1. Screw the nozzle adapter into the Sure Fit® nozzle. Do not over-tighten.
  2. Insert the nozzle adapter into the item to be inflated.
  3. Follow steps 2 through 4 of the “Inflating Tires or Products With Valve Stems” section.
    IMPORTANT: Small items such as volleyballs, footballs, etc. inflate very rapidly. Keep this in mind when setting pressure. Take extra care not to over-inflate.
  4. When the desired pressure is reached, the compressor will automatically stop. Press the Compressor Power Button again to turn off the unit.
  5. Disconnect the adapter from the inflated item.
  6. Unscrew and remove the nozzle adapter from the Sure Fit® nozzle.
  7. Allow the unit to cool, then recharge before storing away.
  8. Store the compressor hose, Sure Fit® nozzle, and nozzle adapter in the storage compartment when not in use.

Visit: EverStart MAXX PPS1CWE 1000 Amp Jump Starter

CARE AND MAINTENANCE

All batteries lose energy from self-discharge over time and more rapidly at higher temperatures. When the unit is not in use, we recommend that the battery be charged at least every 30 days.

From time to time wipe the outside of the appliance with a soft cloth. Do not immerse the appliance in water. There are no user-replaceable parts. Periodically inspect the condition of adapters, connectors, and wires. Contact the manufacturer to replace any components that have become worn or broken.

Battery replacement/disposal

BATTERY REPLACEMENT
The battery should last the service life of the unit. Service life is dependent on several factors including but not limited to the number of recharge cycles, and proper care and maintenance of the battery by the end user. Contact the manufacturer for any information you may need.

SAFE BATTERY DISPOSAL
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed of properly. Recycling is required. Failure to comply with local, state, and federal regulations can result in fines or imprisonment.
Please recycle.

WARNINGS:

  • Do not dispose of the battery in fire as this may result in an explosion.
  • Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can result in injury or fire).
  • Do not expose the battery to fire or intense heat as it may explode.

EverStart JUS750CE Jumper Starter TROUBLESHOOTING

Problem Possible Solution
The unit will not charge Make sure all of the unit’s functions are turned off.
Make sure a suitable gauge extension cord is properly connected to both the unit and a functioning AC outlet.
Unit fails to jump-start Make sure the unit is not being operated in the Compressor mode.

 

 

 

Make sure the unit’s jump-starter power switch is in the on position.

Make sure a proper polarity cable connection has been established.

Check that the unit has a full charge. Recharge the unit if necessary.

Problem Possible Solution
USB power port will not power the appliance If a fault condition exists in either of the USB Ports, the Fault Icon on the LCD screen will flash. Refer to the Important Notes in the “USB Ports” section to remedy any faults.

 

 

 

Make sure that the total draw of all USB devices plugged into the USB Ports does not exceed 2.1A.
Some USB-powered household electronics will not operate with this USB charging/power port. Check the manual of the corresponding electronic device to confirm that it can be used with this type of USB charging/power port.

• Make sure the USB power button has been pressed to turn the USB ports on.

• Check that the unit has a full charge. Recharge the unit if necessary.

LED area light does not come on • Make sure the area light power button has been pressed to turn the area light on.

 

 

 

• Check that the unit has a full charge. Recharge the unit if necessary.

The portable compressor will not inflate • Make sure the unit is not being operated in the Jump Starter mode.

 

 

 

• Make sure the compressor power button has been pressed to turn the compressor on.

• Make sure the Sure Fit® nozzle connector is securely screwed onto the valve stem when attempting to inflate tires; or that the nozzle adapter is securely screwed into the Sure Fit® nozzle connector and is inserted properly into the item to be inflated on all other inflatables.

• The compressor may be overheated. Press the compressor power button to turn the compressor off. Restart after a cooling down period of approximately 30 minutes.

• Check that the unit has a full charge. Recharge the unit if necessary.

EverStart JUS750CE Jumper Starter ACCESSORIES

Recommended accessories for use with your tool may be available from the manufacturer. If you need assistance regarding accessories, please contact the manufacturer at (877) 571-2391.

WARNING: The use of any accessory not recommended for use with this appliance could be hazardous.

EverStart JUS750CE Jumper Starter SERVICE INFORMATION
Whether you need technical advice, repair, or genuine factory replacement parts, contact the manufacturer at (877) 571-2391.

Visit: EverStart MAXX PPS1CWE 1000 Amp Jump Starter

ONE-YEAR LIMITED WARRANTY

The manufacturer warrants this product against defects in materials and workmanship for a period of ONE (1) YEAR from the date of retail purchase by the original end-user purchaser (“Warranty Period”). If there is a defect and a valid claim is received within the Warranty Period, the defective product can be replaced or repaired in the following ways:

  1. Return the product to the manufacturer for repair or replacement at the manufacturer’s option. Proof of purchase may be required by the manufacturer.
  2. Return the product to the retailer where the product was purchased for an exchange (provided that the store is a participating retailer). Returns to the retailer should be made within the period of the retailer’s return policy for exchanges only (usually 30 to 90 days after the sale). Proof of purchase may be required. Please check with the retailer for their specific return policy regarding returns that are beyond the time set for exchanges.

This warranty does not apply to accessories, bulbs, fuses, and batteries; defects resulting from normal wear and tear, accidents; damages sustained during shipping; alterations; unauthorized use or repair; neglect, misuse, abuse; and failure to follow instructions for care and maintenance for the product.

This warranty gives you, the original retail purchaser, specific legal rights and you may have other rights which vary from state to state or province to province. This product is not intended for commercial use.

APPENDIX
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation.

If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not approved by the party responsible for compliance could void the user’s authority to operate the equipment.

SPECIFICATIONS

  • Boost Ampere: 12V DC, 750A peak battery, 375A instantaneous
  • Battery Type: Maintenance-free, sealed lead acid, 12V DC, 9Ah
  • AC Input: 120V AC, 60Hz, 9W
  • Area Light: 2 white LEDs
  • USB Ports: 2.1A (5V DC each) max.
  • Compressor Maximum Pressure: 120 PSI

Sure Fit® is a registered U.S. trademark owned by Baccus Global, LLC. Imported by Baccus Global LLC, 621 NW 53rd St., Suite 450, Boca Raton, FL 33487 www.Baccusglobal.com 1-877-571-2391 RD042820

Visit: EverStart SL097 Jump Starter

FAQs Regarding EverStart JUS750CE Jumper Starter

How long should my Everstart Maxx jump starter be recharged?

51 amp/hours are mine. 51 divided by the charging rate of 1.25 amps per hour indicates that 40.8 hours were needed to charge the battery fully and 32.6 hours were needed to charge it to 80% so it could be utilized.

How long does it take the Everstart Maxx to charge a car battery?

It will take roughly 10–24 hours to fully charge a standard automotive battery with a usual charge amp of 4–8 amperes.

How much time does it take an EverStart JUS750CE Jumper Starter to charge?

Typically, it takes a jump starter between 12 and 24 hours to fully charge from a nearly empty state. But a jump starter’s time to fully charge depends on a variety of circumstances.

When an EverStart JUS750CE Jumper Starter is fully charged, how do you know?

For details, consult the manufacturer’s instructions. This includes what the colors of the light indicators imply. Green denotes a charged battery, while red/orange typically signifies charging.
Note: Utilizing a portable jump starter to jump-start an automobile is equivalent to using traditional jumper wires and a second vehicle.

Can an EverStart JUS750CE Jumper Starter be overcharged?

Any battery’s long-term health suffers if it is charged faster than the rate that is advised. After a good start, many technicians continue to use the jump starter because they believe it to be a quick and simple method of recharging the device. Avoid engaging in this activity. It will have a negative net effect.

Can a car battery be overcharged?

Human error, such as not understanding how to operate a car battery charger, utilizing amp settings that are too high, or selecting the wrong voltage, can also result in overcharging your battery. You risk overcharging your car battery if you leave the charger unattended overnight, which will harm your battery.

Why isn’t my air compressor working?

A virtually empty oil tank may be the sole cause of your compressor’s malfunction. Failure of the power switch could be the cause of the compressor’s inability to turn on if the pressure switch and internal circuits are not in touch. The pressure switch may need to be adjusted to fix this.

How many times can an EverStart JUS750CE Jumper Starter starter be used?

Once jump-started your car’s battery won’t cause any issues. However, if you need to jump-start your battery up to three times per week, it is probably damaged and needs to be replaced.

How long after a jump start should a car be left idle?

If your automobile does manage to start, let it run for a while to assist the battery to become further charged. In the opposite order from how you attached them, unhook the clamps. To ensure that the battery can continue your charge, make sure to drive your car for roughly 30 minutes before stopping once more. If not, you could require a second jump start.

You may also click to visit more Jumper Starters by EverStart:

For More Post Visit: Manuals Dock

Leave a Comment