Welcome to ManualsDock! Read Millions of manuals for free.

Get 20% off and boost your website's speed with Hostinger Cloud Hosting!

Lasko AC3200 Hi-Performance Air Cleaning System User Manual

Lasko AC3200 Hi-Performance Air Cleaning System FEATURE

Lasko

Lasko AC3200 Hi-Performance Air Cleaning System

Lasko AC3200 Hi-Performance Air Cleaning System PRODUCT

About Lasko
Lasko is a company that specializes in the manufacturing of home comfort products, primarily focusing on portable fans, heaters, and other air circulation devices. Founded in 1906, Lasko has a long history in the industry and has established itself as a trusted brand in providing innovative and high-quality products for residential and commercial use.

The company is headquartered in West Chester, Pennsylvania, USA. Lasko designs and manufactures a wide range of products to meet the needs of customers seeking reliable and efficient solutions for cooling, heating, and air circulation. They offer a variety of fan types, including tower fans, pedestal fans, window fans, and table fans, with different features and sizes to cater to diverse preferences.

READ AND SAVE THESE INSTRUCTIONS

WARNINGS
Failure to comply with the warnings listed below may result in electric shock or serious injury. This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.

  • Read all instructions before using the appliance.
  • IMPORTANT – This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
  • Extreme caution is necessary when any appliance is used by or near children or people with disabilities and whenever the appliance is left operating unattended.
  • To avoid fire or shock hazards, plug the appliance directly into a 120V AC electrical outlet.
  • Keep the cord out of heavy traffic areas. To avoid fire hazards, NEVER put the cord under rugs, near heat registers, radiators, stoves, or heaters.
  • To protect against electrical hazards, DO NOT immerse in water or other liquids. 

Do not use near water

  • Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the unit.
  • Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning, or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
  • NEVER drop or insert any object into any openings.
  • DO NOT run the cord under the carpeting.
  • DO NOT cover the cord with throw rugs, runners, or similar coverings.
  • DO NOT route the cord under furniture or appliances. Arrange the cord away from the traffic area so that it will not be tripped over.
  • DO NOT operate any appliance with a damaged cord or plug, if the motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer Service for assistance.
  • Use appliances only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
  • DO NOT use outdoors.
  • DO NOT place anything on top of the unit.
  • NEVER block the air openings, grills/outlets, or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user-serviceable parts. All servicing should be performed by qualified personnel only.
  • WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

The 8-hour TWA Ozone for this product is 0.001 ppmv when tested in a 30 m3 chamber. The product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room of approximately 30 m3.

PRODUCT SPECIFICATIONS AND PARTS

Lasko AC3200 Hi-Performance Air Cleaning System fig-1

  • DIMENSIONS: 9.5” D x 17” W x 27” H
  • WEIGHT: 20.35 lbs

CONTROLS

Lasko AC3200 Hi-Performance Air Cleaning System fig-2

REPLACEMENT PARTS

Lasko AC3200 Hi-Performance Air Cleaning System fig-3

IMPORTANT: To maintain the performance of the air cleaner, use Guardian Technologies GENUINE Replacement Parts only.

AIR CLEANING SYSTEM

Improve your indoor air quality with your new Germ Guardian® Air Cleaning System. Multiple levels of cleaning include a combination filter that captures allergens, and a Charcoal filter to remove odors. UV-C Light Technology enhances germ-killing.

Pre-Filter Screen
Helps optimize the unit performance and extends the life of the filter by capturing larger dust and allergen particles.

Activated Carbon Filter
Traps and controls household odors and harmful VOCs in the home.

Filter
Reduces allergens.

UV-C Light
UV-C Light Technology works with Titanium Dioxide (TiO2) to enhance the elimination of airborne germs. TiO2 is activated by the UV-C light to decompose the remaining odor molecules caused by smoking, cooking, and pets.

Ionizer Option
Negative ions clear the air of dust, mold spores, pollen, pet dander, and odors. They do this by attaching to these positively charged particles in large numbers. This causes the pollen, mold, etc to become too heavy to stay airborne.

AIR CLEANING LAYERS

Lasko AC3200 Hi-Performance Air Cleaning System fig-4

OPERATING INSTRUCTIONS

IMPORTANT: REMOVE ALL BAGS FROM FILTERS BEFORE FIRST USE!
The air purifier is shipped with the filters stored in the filter compartment. The filters are shipped in bags to prevent degradation. Remove filters then remove and discard bags. See page E-8 for filter/replacement instructions.
Note: Proper filter and front panel installation is necessary for unit to turn on.

BEFORE OPERATING THE AIR PURIFIER

  1. Select a firm, level and flat location for the air purifier.
    • For proper air flow, locate the unit at least 1 foot from any wall or furniture.
    • Make sure none of the grills are blocked.
  2. Plug the power cord into a 120V AC outlet.
  3. When moving the air purifier, always lift it by the carrying handle.

OPERATING THE AIR PURIFIER

  1. Turn unit power ON. The control panel power lights will turn on.
    Note: The corresponding control panel lights will turn on depending on features selected.
  2. Select fan speed MODE 1 – 3
    • 1 = low, ultra quiet sleep mode
    • 2 = medium speed
    • 3 = high speed maximum allergen control (both 1 & 2 lights will be lit at this speed)
      UV Bulb Replacement Indicator: The “UV” light on the display will flash when it is time to replace the UV bulb. Replace the bulb according to instructions (E9). Reset the UV light according to the “Reset Indicator Light” instructions (E8).
  3. Select UV-C or Ionizer ON/OFF:
    1. Press button once: UV-C On
    2. Press button twice: Ionizer & UV-C On
    3. Press button third time: Ionizer On
    4. Press button fourth time: both Off
  4. Timer/Unit Sound
    1. If you prefer to run the purifier for a specific number of hours, you can select 2, 4, or 6 hours by pressing the button. (At 6 hours, both the 2 & 4 hour lights will be lit.)
    2. If you want to turn off the beeping sound of the buttons, hold the timer button for a minimum of 5 seconds. Hold again to turn the sound of the buttons back on.

Note: The sound will remain off even if the unit is unplugged, and plugged back in. Filter Replacement Indicator Light: The REPLACE FILTER light on the control panel will illuminate indicating that it is time to replace your filter. Replace the filter. Reset the filter light according to directions (E-8).

OPERATING INSTRUCTIONS

RESETTING THE AIR PURIFIER
The air purifier is equipped with a motor protection device. If activated, the overload warning indicator will initiate and cut off the power. An audible warning “ding” will sound 30 times over 15 seconds. To restart the unit unplug the unit then plug back in and power on.
Note: If the unit continues to shut down, there may still be an abnormal condition and the unit may need service. Call Customer Service.

CLEANING & MAINTENANCE

CLEANING
Always unplug the appliance before you clean it. Never immerse the appliance in water or any other liquid. Never use aggressive or flammable cleaning agents such as bleach or alcohol to clean any part of the appliance.

BODY OF THE APPLIANCE
Regularly clean the inside and outside of the body to prevent dust from collecting on the inside and outside.

  1. Wipe away dust with a soft dry cloth from the body of the appliance.
  2. Clean the air inlet and the air outlet with a soft dry cloth.

PRE-FILTER SCREEN
The pre-filter is designed to collect larger dust and debris and should be cleaned monthly or more frequently depending on use. Remove and clean regularly with the brush attachment of your vacuum cleaner. This will remove the lint and dirt and help maintain the life of the filters. (See filter replacement to locate and remove Pre-filter).

FILTER REPLACEMENT

The “Replace Filter” indicator will light when it is time to replace your filter. Depending on usage and environmental conditions the filters will last approximately 6 months and should be replaced at the same time. The filter will turn from white to gray/black when it is dirty and needs replacing. It is important to maintain and change the filters to continue to optimize the performance of the air purifier.
IMPORTANT: DO NOT wash and re-use the filters. Please contact Customer Service or visit our website www.guardiantechnologies.com to purchase a replacement filter.

REMOVE AND REPLACE FILTER

  1. Turn off and unplug the unit.Lasko AC3200 Hi-Performance Air Cleaning System fig-5
  2. Gently pull the top of the front panel and lift from base.
  3. Remove the filters by pulling the side tabs.
  4. Insert the new filters into the unit – consult the arrows on the filters for correct installation direction. The proper installation sequence should be
    1. Carbon Filter
    2. Filter
  5. Reinstall the Pre-filter Screen by inserting into the tabs on the body of the unit.
    Note: The 2 center tabs on the screen should face outwards, and the arrows located on the side should point up.
  6. Return the front panel: First insert the front panel bottom hooks then close the front panel.Make sure the magnetic closure is secure.
    Note: Proper filter and front panel installation is necessary for unit to turn on.

RESET INDICATOR LIGHT
After the filter OR UV-C bulb has been replaced you will need to reset the indicator light.

  1. The reset button is located IN the side grill (See INSET)
  2. To reset the light, use a paper clip or flat tipped object, insert it into the lower left portion of the grill and push the red button with the tip.
  3. Check to make sure light is off when unit is restarted.Lasko AC3200 Hi-Performance Air Cleaning System fig-6

INSTALLING & REMOVING UV-C BULB

UV Bulb Replacement Indicator: The UV light on the display will flash when its time to replace the UV bulb.Lasko AC3200 Hi-Performance Air Cleaning System fig-7

  1. Pull and remove the front cover and all filters.
  2. After removing the filters, use a Philips head screwdriver to remove 2 screws and detach the UV-C Shield.
  3. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and twisting the bulb 1/4 turn. Remove from unit.Lasko AC3200 Hi-Performance Air Cleaning System fig-8
  4. The UV-C Bulb is reinstalled by reversing the process in Step 3.
  5. Re-attach the UV-C Shield.
  6. Reset the UV light according to the “Reset Indicator Light” instructions (E8).

Replacement bulb: LB9200
IMPORTANT: The UV-C Bulb should be replaced every 10 – 12 months depending on use.

What is CADR?
CADR stands for “Clean Air Delivery Rate,” which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particles from things like tobacco smoke and plant pollens from the room.

Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
Refer to website for individual model CADR numbers.

TROUBLESHOOTING GUIDE

Lasko AC3200 Hi-Performance Air Cleaning System fig-9

LIMITED WARRANTY

To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. In order to be eligible for this Limited Warranty, an original sales receipt or comparable substitute proof of purchase bearing the date of original purchase is required. Refer to the original product carton or specific product/model page on the Guardian Technologies website for warranty length for your particular model. This warranty applies only to the original purchaser of this product from the original date of purchase. This warranty covers product purchased from authorized distributors only.

This warranty applies to repair or replacement of product found to be defective in materials or workmanship. This warranty does not apply to damage resulting from unusual wear, commercial, abusive, unreasonable use or supplemental damage. This warranty does not cover damage from unauthorized repairs or from any use not in accordance with the instruction manual. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.

If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. All warranty repairs must be completed by Guardian Technologies LLC. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state
to state in the U.S.A.)

To submit product under warranty the complete machine must be delivered pre-paid to Guardian Technologies LLC. Please include complete information including: the problem, the model number of the product, the day of purchase, and a copy of the original sales receipt along with your name, address, and telephone (email optional). Address returns to the attention of: Customer Service, at the address below. Additional questions or comments can be made toll free to the number listed below.

USA and Canada
Guardian Technologies LLC 26251 Bluestone Blvd. Euclid, Ohio 44132 1.866.603.5900
www.guardiantechnologies.com

Please go to www.guardiantechnologies.com to register your product. We consider the registration process important to ensuring superior service to our customers, however submitting the warranty registration is optional and does not affect your rights to utilize this warranty according to the conditions stated above. Additional copies of the instruction manual can be obtained by accessing and printing directly from our website or calling customer service.

FAQS About Lasko AC3200 Hi-Performance Air Cleaning System

How frequently should an air purifier’s filter be changed?

each 6 to 12 months

How long should my air purifier run each day?

We advise that you leave your air purifier on all day long. There are suitable ways to operate your air purifier to maximise its function, nevertheless, if this is not feasible for your circumstances.

Can an air purifier be left on continuously?

You can leave your air purifier on all day without risk. However, you must be sure to clean the filters around once a month. If the filters are not cleaned frequently, they can accumulate large amounts of dust and allergens that may be dangerous to people who are already sensitive.

How long does it take for an air purifier to start working?

Having said that, you might start seeing changes in the air in a half-hour with a good, high-quality air purifier. You might notice a noticeable improvement in your air quality after a few hours.

How long should an air purifier be run?

Leave it on for at least 4 hours each day. It is advised to run an air purifier for at least eight hours if there is a scent in the space. By doing this, it may effectively purify the inside air and quickly release any dangerous indoor gases outside.

How can I tell whether the filter in my air purifier needs to be changed?

A PM2. 5 air quality monitor, commonly known as a particulate counter, is the ideal tool for determining when to update a HEPA filter. To make sure the air in your house is at acceptable levels, utilise an air quality metre. Performance of a HEPA filter degrades with time.

During the night, should I turn off my air purifier?

Yes. It is highly advised to use your air purifier at night if you want to benefit from better air quality. It is best to continuously filter pollutants and allergens out of your air because they are still there at night.

Where should I put a purifier in my home?

An air purifier should be placed 3-5 feet above the ground. At this height, they may take advantage of the room’s airflow. Your air purifier will be in this ideal range and work at its best if you place it on top of a sturdy table.

How can I determine whether my air cleaner is working?

The best method for figuring out whether your air purifier is working is to conduct tests using a separate indoor air quality monitor. These devices allow you to assess the efficiency of your air purifier by real-time analysing the air quality in your house.

For more manuals for Lasko, Visit Manualsdock

[embeddoc url=”https://manualsdock.com/wp-content/uploads/2023/07/Lasko-AC3200-Hi-Performance-Air-Cleaning-System-User-Manual.pdf” download=”all”]

Leave a Comment